SparkQuote NEC calculators
ai.sparkquote/nec-calculatorsVersion 1.0.1NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
Status
Responds183 msAnswered our handshake without sign-in.- Last checked
- Nov 14, 2026, 13:33 UTC
- Latency
- 183 ms
- Remotes responding
- 1 of 1
- Sign-in
- No sign-in
- Hosting
- Hosted outside the EU (detected)
- Registry data as of
- Nov 14, 2026, 22:14 UTC
Data from the official MCP Registry, checked by run.zero. How we check
Connect
Streamable HTTP
https://sparkquote.ai/mcpResponds183 msNo sign-in
Claude Code
claude mcp add --transport http nec-calculators https://sparkquote.ai/mcpClaude Desktop and claude.ai
Settings > Connectors > Add custom connector
Name: nec-calculators
Remote MCP server URL: https://sparkquote.ai/mcpCursor
{
"mcpServers": {
"nec-calculators": {
"url": "https://sparkquote.ai/mcp"
}
}
}VS Code
code --add-mcp '{"name":"nec-calculators","type":"http","url":"https://sparkquote.ai/mcp"}'Built your own server? run.zero hosts MCP servers on European infrastructure.
Tools
10 tools
Read-only | Idempotent | Open world | ||
|---|---|---|---|---|
bid_calculatorElectrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)). | No | Yes | Yes | No |
box_fillMinimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor. | No | Yes | Yes | No |
conduit_fillPercent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5. | No | Yes | Yes | No |
load_calculatorDwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA. | No | Yes | Yes | No |
nec_ampacityAllowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits. | No | Yes | Yes | No |
ohms_lawOhm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated. | No | Yes | Yes | No |
panel_scheduleLays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance. | No | Yes | Yes | No |
voltage_dropVoltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase). | No | Yes | Yes | No |
watts_to_ampsCurrent drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value. | No | Yes | Yes | No |
wire_sizeMinimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors. | No | Yes | Yes | No |