ivive.app
app.ivive/iviveVersion 1.0.3Human hepatic clearance from in-vitro CLint, with the error band measured on known drugs.
Status
Responds142 msAnswered our handshake without sign-in.- Last checked
- Nov 14, 2026, 13:36 UTC
- Latency
- 142 ms
- Remotes responding
- 1 of 1
- Sign-in
- No sign-in
- Hosting
- EU hosting detected (detected, not a legal statement)
- Registry data as of
- Nov 14, 2026, 22:14 UTC
Data from the official MCP Registry, checked by run.zero. How we check
Connect
Streamable HTTP
https://api.ivive.app/mcp/Responds142 msNo sign-in
Claude Code
claude mcp add --transport http ivive https://api.ivive.app/mcp/Claude Desktop and claude.ai
Settings > Connectors > Add custom connector
Name: ivive
Remote MCP server URL: https://api.ivive.app/mcp/Cursor
{
"mcpServers": {
"ivive": {
"url": "https://api.ivive.app/mcp/"
}
}
}VS Code
code --add-mcp '{"name":"ivive","type":"http","url":"https://api.ivive.app/mcp/"}'Built your own server? run.zero hosts MCP servers on European infrastructure.
Tools
6 tools
Read-only | Idempotent | Open world | ||
|---|---|---|---|---|
calc_clhepHepatic and plasma clearance from in-vitro CLint, fu,mic and fu,p (IVIVE), with the observed-CL band and applicability warnings. If fu,p or fu,mic came from predict_inputs, tell the user the result rests on predicted inputs. | No | Yes | Yes | No |
input_sensitivityHow far plasma CL moves as each input is varied over a range, e.g. a predicted fu,p over its 50% range. | No | Yes | Yes | No |
predict_inputsPredict fu,p and fu,inc from a SMILES, with structure-only human CL and Vss as second opinions. Predictions, not measurements; check the applicability verdict. | No | Yes | Yes | No |
scale_to_humanPredict human plasma CL from observed animal in-vivo CL (rat, dog, monkey), every applicable method with its measured error. Observed animal CL only, never predicted. | No | Yes | Yes | No |
similar_drugsNearest reference drugs to a SMILES (Tanimoto, Morgan radius 2), each with measured human plasma CL and the CL IVIVE predicted from its measured inputs. Use it to judge how far to trust calc_clhep for this chemotype: if IVIVE missed on the neighbours, expect it to miss here. Returns neighbours only, not a prediction for the query. | No | Yes | Yes | No |
target_clintThe in-vitro CLint an assay must read for a compound to reach a target plasma clearance (mL/min/kg): calc_clhep run backwards, e.g. to set a CLint cut-off for a screening cascade. Needs fu,mic and fu,p; refuses a target at or above the liver blood flow ceiling and returns that ceiling. Uncorrected IVIVE, so no error band. | No | Yes | Yes | No |
Details
- Registry status
- Active
- Published
- Oct 29, 2026
- Updated
- Oct 29, 2026
- Repository
- Not given
- Categories
- Uncategorized
- GDPR
- Not declared