Skip to main content

Spark Pack

io.github.Nero-Engine/spark-packVersion 1.1.0

Cable sizing, Part P, certificate checks and G98/G99 for UK electricians' AI assistants

Status

Responds147 msAnswered our handshake without sign-in.

Registry data may be out of date

We could not refresh it, so this page shows the last copy.
Last checked
Nov 14, 2026, 14:40 UTC
Latency
147 ms
Remotes responding
1 of 1
Sign-in
No sign-in
Hosting
Hosted outside the EU (detected)
Registry data as of
Nov 14, 2026, 21:12 UTC

Data from the official MCP Registry, checked by run.zero. How we check

Connect

Streamable HTTP
https://spark-pack.nerolabs.workers.dev/mcpResponds147 ms
No sign-in

Claude Code

claude mcp add --transport http spark-pack https://spark-pack.nerolabs.workers.dev/mcp

Claude Desktop and claude.ai

Settings > Connectors > Add custom connector
Name: spark-pack
Remote MCP server URL: https://spark-pack.nerolabs.workers.dev/mcp

Cursor

{
  "mcpServers": {
    "spark-pack": {
      "url": "https://spark-pack.nerolabs.workers.dev/mcp"
    }
  }
}

VS Code

code --add-mcp '{"name":"spark-pack","type":"http","url":"https://spark-pack.nerolabs.workers.dev/mcp"}'

Built your own server? run.zero hosts MCP servers on European infrastructure.

Host your own MCP server on run.zero

Tools

7 tools

Tools of Spark Pack
Read-only
Idempotent
Open world
check_certificateChecks a filled EIC, Minor Works certificate or EICR (shape from get_certificate_schema) and returns `ready_to_transfer`, every missing required field by path, errors (readings that fail: insulation resistance under 1 megohm at 500 V, measured Zs above the maximum for the breaker, RCD trip times too slow, wrong polarity, an EICR marked satisfactory with a C1 or C2) and warnings (Zs above 80% of maximum, mismatched ring readings, low insulation resistance). Contractor fields left blank are filled from `trade`. Returns the (prefilled) data back.NoYesYesNo
check_grid_connectionFor solar PV, batteries, V2G chargers, EV chargers and heat pumps in Great Britain: says which network operator process applies and when. Generation: G98 (fully type tested, 16 A / 3.68 kW per phase or less: install, then notify within 28 days) or G99 (apply and wait for acceptance before installing), counting existing generation and battery inverters. Demand: the ENA EV charge point and heat pump form (connect and notify within 28 days if every criterion is met, otherwise apply first), with each criterion marked true, false or null (not yet known). Returns `generation`, `demand`, `facts_to_put_on_the_form` (prefilled from inputs and `trade`), `missing_facts` and sources. Example: 5 kW solar plus a 5 kW battery inverter on single phase: {"supply_phases":1,"new_equipment":[{"type":"solar_pv","rating_kw":5,"type_tested":true},{"type":"battery","rating_kw":5,"type_tested":true}]}.NoYesYesNo
check_part_pAnswers whether domestic electrical work in England or Wales must be notified to building control under Part P of the Building Regulations, with the reason and what to do next (self-certify through a competent person scheme within 30 days, or tell building control before starting). England and Wales differ: in Wales kitchens and outdoor areas are still special locations. Returns `notifiable` (true or false), `answer`, `reason`, `what_to_do`, `must_check` and sources. Scotland and Northern Ireland return not_covered. Example: adding a socket in a kitchen in England: {"nation":"england","work":"add_to_or_alter_existing_circuit","locations":["kitchen"]}.NoYesYesNo
get_certificate_schemaReturns the fields an Electrical Installation Certificate (eic), Minor Electrical Installation Works Certificate (minor_works) or Electrical Installation Condition Report (eicr) needs, as a JSON Schema the assistant fills from the job notes and test readings (spark-pack-certs-1.0 (for BS 7671:2018+A4:2026 certificates)). Includes which certificate to use when, and the contractor block prefilled from `trade` if given. check_certificate checks the filled object. Field names are Spark Pack's own; the electrician transfers the values to the official form in their scheme portal or software.NoYesYesNo
list_capabilitiesLists Spark Pack's tools, the regulations edition it targets, what it covers (nations, circuit types, cable types, installation methods) and what it deliberately does not do. Free, needs no input.NoYesYesNo
size_cableSizes a UK final circuit or sub-main and shows the working: design current (with cooker diversity), protective device rating, the smallest cable size that passes current-carrying capacity, voltage drop (3% lighting, 5% other) and earth fault loop impedance (Zs against the maximum for B, C or D breakers), plus a cpc adiabatic check. Returns `recommended` (size and every check with status pass, fail, indicative_pass, needs_input), `sizes_considered` (one line per size), `must_check_against_regs` (points the electrician confirms in BS 7671) and sources. Current-carrying capacity comes from a cautious heat-flow model, not BS 7671 tables, so it is marked indicative; give `cable_size_mm2` plus `tabulated_capacity_a` from the regs for a firm check. Voltage drop and Zs are calculated from physics and are firm for the inputs given. Typical call: a 9.5 kW shower on an 18 m run clipped direct: {"circuit_type":"shower","load_kw":9.5,"run_length_m":18,"installation_method":"clipped_direct"}.NoYesYesNo
trade_profileChecks the electrician's own business details (Nero Trade Profile v1: trading name, Companies House number, competent person scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration or company number. The same object, given as `trade` to the other tools, prefills certificates and grid forms. Spark Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.NoYesYesNo