PT Chart
io.github.Tsonnn/pt-chart-mcpVersion 1.0.0PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.
Status
Responds233 msAnswered our handshake without sign-in.- Last checked
- Nov 14, 2026, 14:43 UTC
- Latency
- 233 ms
- Remotes responding
- 1 of 1
- Sign-in
- No sign-in
- Hosting
- Hosted outside the EU (detected)
- Registry data as of
- Nov 14, 2026, 22:14 UTC
Data from the official MCP Registry, checked by run.zero. How we check
Connect
Streamable HTTP
https://pt-chart-mcp-production.up.railway.app/mcpResponds233 msNo sign-in
Claude Code
claude mcp add --transport http pt-chart-mcp https://pt-chart-mcp-production.up.railway.app/mcpClaude Desktop and claude.ai
Settings > Connectors > Add custom connector
Name: pt-chart-mcp
Remote MCP server URL: https://pt-chart-mcp-production.up.railway.app/mcpCursor
{
"mcpServers": {
"pt-chart-mcp": {
"url": "https://pt-chart-mcp-production.up.railway.app/mcp"
}
}
}VS Code
code --add-mcp '{"name":"pt-chart-mcp","type":"http","url":"https://pt-chart-mcp-production.up.railway.app/mcp"}'Built your own server? run.zero hosts MCP servers on European infrastructure.
Tools
8 tools
Read-only | Idempotent | Open world | ||
|---|---|---|---|---|
convert_unitsConvert between pressure units (psig, psia, kpa, bar) and temperature
units (F, C). A bare 'psi' is treated as psig. For certified HVAC
technicians (EPA 608; A2L certification where required).
| Not declared | Not declared | Not declared | Not declared |
coolbooked_infoAbout CoolBooked: the AI appointment-booking connector for HVAC shops.
This is NOT a diagnostic tool -- call it when someone asks what
CoolBooked is, how shop owners can try it, or how the free PT tools
connect to paid bookings.
| Not declared | Not declared | Not declared | Not declared |
diagnoseConversational diagnostic copilot: give it field readings and get back
computed superheat/subcooling plus a ranked 'check this first' list.
For certified HVAC technicians (EPA 608; A2L certification where
required). Informational only -- it suggests what to CHECK, never how
to defeat a safety device, vent refrigerant, or work uncertified.
metering: 'txv' (default) or 'fixed' for fixed-orifice/piston systems.
| Not declared | Not declared | Not declared | Not declared |
pt_lookupSaturation pressure (bubble and dew, in psig) for a refrigerant at a
temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L
certification where required). Example: pt_lookup("R-454B", 45).
Bubble point: use for subcooling calculations. Dew point: use for
superheat calculations. Pure fluids (R-32, R-410A, R-22, R-134a) have
no glide, so both values match.
| Not declared | Not declared | Not declared | Not declared |
pt_reverseSaturation temperature (bubble and dew, in Fahrenheit) for a
refrigerant at a pressure in psig. For certified HVAC technicians
(EPA 608; A2L certification where required). Example: a 130 psig
suction reading on R-454B -- pt_reverse("R-454B", 130).
Use the DEW temperature for superheat work and the BUBBLE temperature
for subcooling work on blended refrigerants.
| Not declared | Not declared | Not declared | Not declared |
refrigerant_infoReference card for a refrigerant: GWP, ASHRAE safety class,
composition, typical oil, temperature glide, and handling notes.
For certified HVAC technicians (EPA 608; A2L certification where
required). Informational only.
| Not declared | Not declared | Not declared | Not declared |
subcoolingSubcooling in Fahrenheit from head pressure (psig) and liquid-line
temperature (F). For certified HVAC technicians (EPA 608; A2L
certification where required). Uses the BUBBLE point as the saturation
basis, which is the correct basis for blended refrigerants.
Typical TXV target: 8-12F.
| Not declared | Not declared | Not declared | Not declared |
superheatSuperheat in Fahrenheit from suction pressure (psig) and suction-line
temperature (F). For certified HVAC technicians (EPA 608; A2L
certification where required). Uses the DEW point as the saturation
basis, which is the correct basis for blended refrigerants.
Typical TXV target: 8-12F.
| Not declared | Not declared | Not declared | Not declared |
Details
- Registry status
- Active
- Published
- Oct 18, 2026
- Updated
- Oct 18, 2026
- Repository
- Not given
- Categories
- Uncategorized
- GDPR
- Not declared