Skip to main content

PT Chart

io.github.Tsonnn/pt-chart-mcpVersion 1.0.0

PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.

Status

Responds233 msAnswered our handshake without sign-in.

Registry data may be out of date

We could not refresh it, so this page shows the last copy.
Last checked
Nov 14, 2026, 14:43 UTC
Latency
233 ms
Remotes responding
1 of 1
Sign-in
No sign-in
Hosting
Hosted outside the EU (detected)
Registry data as of
Nov 14, 2026, 22:14 UTC

Data from the official MCP Registry, checked by run.zero. How we check

Connect

Streamable HTTP
https://pt-chart-mcp-production.up.railway.app/mcpResponds233 ms
No sign-in

Claude Code

claude mcp add --transport http pt-chart-mcp https://pt-chart-mcp-production.up.railway.app/mcp

Claude Desktop and claude.ai

Settings > Connectors > Add custom connector
Name: pt-chart-mcp
Remote MCP server URL: https://pt-chart-mcp-production.up.railway.app/mcp

Cursor

{
  "mcpServers": {
    "pt-chart-mcp": {
      "url": "https://pt-chart-mcp-production.up.railway.app/mcp"
    }
  }
}

VS Code

code --add-mcp '{"name":"pt-chart-mcp","type":"http","url":"https://pt-chart-mcp-production.up.railway.app/mcp"}'

Built your own server? run.zero hosts MCP servers on European infrastructure.

Host your own MCP server on run.zero

Tools

8 tools

Tools of PT Chart
Read-only
Idempotent
Open world
convert_unitsConvert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required). Not declaredNot declaredNot declaredNot declared
coolbooked_infoAbout CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings. Not declaredNot declaredNot declaredNot declared
diagnoseConversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety device, vent refrigerant, or work uncertified. metering: 'txv' (default) or 'fixed' for fixed-orifice/piston systems. Not declaredNot declaredNot declaredNot declared
pt_lookupSaturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations. Pure fluids (R-32, R-410A, R-22, R-134a) have no glide, so both values match. Not declaredNot declaredNot declaredNot declared
pt_reverseSaturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and the BUBBLE temperature for subcooling work on blended refrigerants. Not declaredNot declaredNot declaredNot declared
refrigerant_infoReference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only. Not declaredNot declaredNot declaredNot declared
subcoolingSubcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F. Not declaredNot declaredNot declaredNot declared
superheatSuperheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F. Not declaredNot declaredNot declaredNot declared

Details

Registry status
Active
Published
Oct 18, 2026
Updated
Oct 18, 2026
Repository
Not given
Categories
Uncategorized
GDPR
Not declared

Are you the operator? Claim this listing